厂房降温用冷风机是我公司专为厂房降温、流水线产品冷却、岗位冷却而设计的一款产品,其工作原理大致如下:以环境温度30℃为例,冷却送风机抽取30℃空气,经过蒸发器后快速降温至20℃后送到厂房内,可把整个厂房温度保持在舒适的状态下。
标准型冷风机风冷式Standard air cooler air cooled(一)
| 项目Item / 型号Model | BN/02AS | BN-03AS | BN-05AS | BN-08AD | BN-10AD | BN-12AD | BN-15AD | BN-20AD | BN-25AD | BN-30AD | BN-40AD | 冷冻能力Power supply | KW(50HZ) | 5.67 | 8.86 | 14.5 | 21.8 | 29 | 34.4 | 44.5 | 60 | 76 | 90 | 120 | Kcal/h | 4872 | 7216 | 11990 | 18748 | 24089 | 29059 | 379+65 | 50805 | 62952 | 74820 | 99846 | 电源Power supply | 1N-22V | 3N-380V/50HZ | 制冷剂 Refrigerane | R | R22 | 压缩机功率Compressor power | Kw | 1.5 | 2.2 | 4.22 | 3*2 | 4.22*2 | 4.68*2 | 8.2+4.22 | 8.1*2 | 9.15*3 | 8.1*3 | 8.1*4 | 出风管径Ourlet Pipe Inner Diam | mm | 100-150 | 100-150 | 100-150 | 100-150 | 100-150 | 100-150 | 100-150 | 150-200 | 150-200 | 150-200 | 200-250 | 控温范围Confrol Temperalute Rangc | °C | 5-25 | 5-25 | 5-25 | 5-25 | 5-25 | 5-25 | 5-25 | 5-25 | 5-25 | 5-25 | 5-25 | 风量Wrnd Volume | m3/h | 200-400 | 300-550 | 550-1000 | 800-2000 | 1100-2400 | 1500-2800 | 1800-3200 | 2200-3800 | 2700-4500 | 3100-5500 | 3600-6300 | 风速Wrnd Speed | m/s | 8-12 | 8-12 | 8-14 | 8-14 | 8-14 | 8-14 | 8-14 | 8-14 | 8-14 | 8-14 | 8-14 | 外形尺寸 Size | 长Length | MM | 860 | 900 | 1100 | 1490 | 1490 | 1550 | 1700 | 1950 | 2050 | 2500 | 1950 | 宽Width | MM | 540 | 610 | 735 | 780 | 780 | 780 | 830 | 910 | 850 | 910 | 1800 | 高Height | MM | 930 | 1125 | 1272 | 1460 | 1460 | 1510 | 1510 | 1600 | 1700 | 1700 | 1700 | 重量Weight | KG | 120 | 133 | 169 | 275 | 350 | 378 | 520 | 600 | 780 | 880 | 1260 |
| |
|
|
标准型冷风机风冷式Standard air cooler air cooled(二)
| 项目Item / 型号Model | BN/03WS | BN/05WS | BN/08WD | BN/10WD | BN/12WD | BN/15WD | BN/20WD | BN/25WD | BN/30WT | BN/40WF | | 冷冻能力Power supply | KW(50HZ) | 9.34 | 16.1 | 24.8 | 32.2 | 38 | 49.1 | 66 | 76 | 99 | 132 | | Kcal/h | 8251 | 13690 | 21375 | 27370 | 32994 | 43120 | 57748 | 70120 | 85303 | 110984 | | 电源Power supply | 3N-380V/415V-50HZ | 制冷剂 Refrigerane | R | R22 | 压缩机功率Compressor power | Kw | 2.81 | 3.46 | 3.31*2 | 3.46*2 | 3.76*2 | 3.46+6.6 | 6.6*2 | 7.4*2 | 6.6*3 | 6.6*4 | | 出风管径Ourlet Pipe Inner Diam | mm | 100/150 | 100/150 | 100/150 | 100/150 | 100/150 | 100/150 | 150-200 | 150-200 | 150-200 | 200-250 | | 控温范围Confrol Temperalute Rangc | °C | 0-5 5-10 | 0-5 5-10 | 0-5 5-10 | 0-5 5-10 | 0-5 5-10 | 0-5 5-10 | 0-5 5-10 | 0-5 5-10 | 0-5 5-10 | 0-5 5-10 | | 风量Wrnd Volume | m3/h | 300-550 | 550-1000 | 800-2000 | 1100-2400 | 1500-2800 | 1800-3200 | 2200-3800 | 2700-4500 | 3100-5500 | 3600-6300 | | 风速Wrnd Speed | m/s | 8-12 | 8-14 | 8-14 | 8-14 | 8-14 | 8-14 | 8-14 | 8-14 | 8-14 | 8-14 | | 外形尺寸 Size | 长Length | MM | 900 | 1100 | 1490 | 1490 | 1550 | 1700 | 1950 | 2050 | 2500 | 1950 | | 宽Width | MM | 610 | 735 | 780 | 780 | 780 | 830 | 910 | 850 | 910 | 1800 | | 高Height | MM | 1125 | 1272 | 1460 | 1460 | 1510 | 1510 | 1600 | 1700 | 1700 | 1700 | | 重量Weight | KG | 133 | 169 | 275 | 350 | 378 | 520 | 600 | 780 | 880 | 1260 | |
|
|
|
由于高温环境影响工作效率,当人处于28~32℃的工作环境时,工作效率开始下降,并且更容易疲劳。当温度达到32℃以上时,人的注意力和灵敏度也开始受到影响,我公司研制的厂房降温用冷风机可以有效的把厂房内的温度保持15~25℃,可以极大的改善工作环境,提供工人生产效率。
厂房降温用冷风机特点:
1、 多重防堵过滤设计,有效过滤粉尘、颗粒
2、 送风量大,噪音更小
3、 可24小时连续不停机工作,运行稳定
4、 防水设计,可直接放置在室外
5、 安装简单,用户只需把冷风机管路连接到厂房内即可运行
冷风机系统原理图