1.1、10KW水冷式冷水机,是利用蒸发器使水与冷媒进行热交换,冷媒在吸收水中的热量,使水降温产生冷水后通过压缩机的作用将热量带至壳管式冷凝器,由冷媒与水进行热交换﹐使水吸收热量后通过水管将热量带出外部的冷却塔散失、冷却。
水冷式冷水机参数配置表一 Technical parameters table of Air-cooled Industrial chiller(一)
| 参数Parameter / 型号Model | BN-03WS | BN-04WS | BN-05WS | BN-06WS | BN-08WD | BN-10WD | BN-12WD | BN-15WD | 制冷量 | KW(50HZ) | 9.34 | 12.4 | 16.1 | 19 | 24.8 | 32.2 | 38 | 49.1 | Cooling capacity | Kcal/h | 8032 | 10664 | 13846 | 16340 | 21328 | 27370 | 32680 | 42226 | 输入功率Mator ipupt | KW | 3.2 | 3.68 | 4.21 | 4.51 | 7.36 | 8.42 | 9.02 | 11.56 | 运行电流 Maximun Current | A | 6.07 | 6.75 | 9.8 | 10.5 | 13.5 | 19.6 | 21 | 24 | 电源Power Supply | 3N-380V / 415V 50HZ | 冷媒/制冷剂Refrigerant | 名称Name | R22 | 充注量Charge | KG | 1.7 | 2.2 | 2.8 | 3.4 | 2.2*2 | 2.8*2 | 3.4*2 | 4.2*2 | 控制方法Control Type | 毛细管Capillary Tube/外平衡热力膨胀阀Externabalanced Thermostatic Expansion Valve | 压缩机 CoolingWater | 类型Type | 全封闭涡旋式或活塞式 Hermetic Scroll or Piston | 功率Motor | kw | 2.81 | 3.31 | 3.46 | 3.76 | 3.31*2 | 3.46*2 | 3.76*2 | 3.46+6.6 | 冷却水Chilled Water | 水量Flow | M3/h | 2.1 | 3.2 | 4.1 | 4.8 | 6.4 | 8.2 | 9.6 | 11.9 | 进出水管径In/Out Pipe Size | G1" | G1" | G1" | G1" | G1-1/2" | G2" | G2" | G2" | 冷冻水Chilled Water | 水量Flow | M3/h | 1.65 | 2.14 | 2.8 | 3.3 | 4.3 | 5.6 | 6.6 | 8.5 | 水箱Tank | M3 | 0.038 | 0.038 | 0.065 | 0.08 | 0.188 | 0.188 | 0.188 | 0.285 | 进出水管径In/Out Pipe Size | G3/4" | G3/4" | G1" | G1" | G1-1/2" | G2" | G2" | G2" | 水泵 Water Pump | 功率Motor | KW | 0.375 | 0.375 | 0.75 | 0.75 | 0.75 | 1.5 | 1.5 | 1.5 | 压力Pressure | Kpa | 242 | 242 | 290 | 290 | 290 | 205 | 205 | 205 | 外形尺寸 Size | 长Length | MM | 830 | 830 | 1080 | 1080 | 1300 | 1300 | 1300 | 1680 | 宽Width | MM | 460 | 460 | 580 | 580 | 610 | 610 | 710 | 775 | 高Height | MM | 120 | 140 | 150 | 200 | 210 | 290 | 310 | 400 | 重量Weight | KG | 1020 | 1020 | 1230 | 1230 | 1445 | 1445 | 1445 | 1480 |
| |
|
|
水冷式冷水机参数配置表二 Technical parameters table of Air-cooled Industrial chiller(二)
| 参数Parameter / 型号Model | BN-20WD | BN-25WD | BN-30WT | BN-36WT | BN-40WF | BN-50WF | BN-60WF | 制冷量 | KW(50HZ) | 66 | 76 | 99 | 114 | 132 | 152 | 198 | Cooling capacity | Kcal/h | 56760 | 65360 | 85140 | 98040 | 113520 | 130720 | 170280 | 输入功率Mator ipupt | KW | 15.4 | 17 | 23.6 | 26 | 30.2 | 33.5 | 39.6 | 运行电流 Maximun Current | A | 29.6 | 31.8 | 45.6 | 48.6 | 58.3 | 62.3 | 76.2 | 电源Power Supply | 3N-380V / 415V 50HZ | 冷媒/制冷剂Refrigerant | 名称Name | R22 | 充注量Charge | KG | 5*2 | 6.3*2 | 5*3 | 6.2*3 | 5*4 | 6.2*4 | 5*6 | 控制方法Control Type | 外平衡热膨胀阀ExternalBalanced Thermostatic Expansion Valve | 压缩机 CoolingWater | 类型Type | 全封闭涡旋式或活塞式 Hermetic Scroll or Piston | 功率Motor | kw | 6.6*2 | 7.4*2 | 6.6*3 | 7.4*3 | 6.6*4 | 7.4*4 | 6.6*6 | 冷却水Chilled Water | 水量Flow | M3/h | 15.9 | 18.2 | 21.32 | | 31.7 | 36.4 | 47.5 | 进出水管径In/Out Pipe Size | G2" | G2" | G2-1/2" | G3" | G3" | G3" | G3" | 冷冻水Chilled Water | 水量Flow | M3/h | 11.3 | 13.1 | 17.06 | 19.7 | 22.8 | 26.2 | 34 | 水箱Tank | M3 | 0.28 | 0.4 | 0.4 | 0.4 | 0.55 | 0.3 | - | 进出水管径In/Out Pipe Size | G2-1/2" | G2-1/2" | G2-1/2" | G3" | G3" | G3" | G3" | 水泵 Water Pump | 功率Motor | KW | 2.2 | 2.2 | 3.75 | 3.75 | 3.75 | 3.75 | - | 压力Pressure | Kpa | 220 | 220 | 250 | 250 | 250 | 250 | 250 | 外形尺寸 Size | 长Length | MM | 1680 | 1880 | 2200 | 2200 | 2400 | 2400 | 2400 | 宽Width | MM | 775 | 914 | 1000 | 1000 | 1000 | 1000 | 1150 | 高Height | MM | 1480 | 1650 | 1650 | 1650 | 1650 | 1650 | 1650 | 重量Weight | KG | 440 | 580 | 690 | 760 | 900 | 1000 | 1000 |
| |
|
1、10KW水冷式冷水机,体积相比于风冷式冷水机要小,整体性能稳定,相同匹数情况下水冷式冷水机制冷量要比风冷式冷水机多出约20%。
2、10KW水冷式冷水机内部主要配置:
2.1、压缩机:美国谷轮3HP
2.2、水泵:不锈钢南方泵 流量2.5m³/h,压力2KG
2.3、水箱:不锈钢材质,容积50升
2.4、蒸发器:壳管式
2、水冷式冷水机组在运行过程中,长期运行会有污垢或其它杂质,会影响到制冷效果。为了保证延长使用寿命,使机组达到状态,应定期做好维护、保养工作,确保冷水机组运行品质,提高生产效率。
3、用户检查及保养项目:
3.1、定期检查冷水机电流是否稳定,压缩机运转声音是否正常,10KW水冷式冷水机正常工作时电压为380V,电流在6A-9A范围内为正常状态。
3.2、定期检查冷水机是否有冷媒泄漏:一般正常状态下水冷式冷水机低压表指针在3KG~3.5KG,高压在15KG~18KG。(保护装置:如果制冷系统发生泄漏,当低压表低于1KG后冷水机会报警并停机,并且开不了机)
3.3、水冷式冷水机在使用了6个月后应该做一次常规保养,主要保养包括:清理冷却水塔水盘内的杂质及污泥、清洗冷却水管管道内的杂物及清洗壳管式冷凝器铜管壁上的水垢。
10KW水冷式冷水机原理图