品牌
其他厂商性质
苏州市所在地
Operating Modes | |||
Model | iX Series II | i Series II | |
Modes | AC, DC or AC+DC | AC or DC |
AC Mode Output | |
Frequency | Range: 16.00-1000 Hz (Note: Voltage on 300 V range derates from 300 Vrms max at 500 Hz to 150 Vrms max at 1000 Hz; See V-F rating chart. below) |
Total Power | 3001i/iX: 3000 VA, 5001i/iX: 5000 VA, 9003i/iX: 3000 VA 3ø, with mode iX: 9000 VA 1ø, 10001i/iX: 10000 VA, 15001i/iX: 15000 VA, 15003i/iX: 5000 VA/ø 3ø, with mode iX: 15000 VA/ø 1ø |
Load Power Factor | 0 to unity at full output VA |
AC Mode Voltage | |||
Voltage Ranges | Range | VLow | VHigh |
AC | 0-150 V | 0-300 V | |
AC+DC | 0-150 V | 0-300 V | |
Load Regulation (with ALC on) | < 0.2% | ||
Load Regulation (with ALC off) | < 0.5% DC to 100 Hz, < 0.6% 100 Hz to 500 Hz in high voltage range, < 2.2% 100 Hz to 500 Hz in low voltage range, < 3% 500 Hz to 1000 Hz | ||
Line Regulation | < 0.1% for 10% line change | ||
Output Noise (20 kHz to 1 MHz) | < 250 mVrms typ., < 500 mVrms max. | ||
Harmonic Distortion (Linear) | < 1% from 16 - 66 Hz, < 2% at 400 Hz, < 3% at 800 Hz (Full resistive load) | ||
DC Offset | < 20 mV External Amplitude Modulation: Depth: 0 - 10 %, Frequency: DC - 2 KHz | ||
Isolation Voltage | 300 Vrms output to chassis |
AC Mode Current | ||||
Model | Model | 3001 i/iX | 5001 i/iX | 9003 i/iX 3ø |
Steady State AC Current | 300 V range | 11.1 | 18.5 | 11.1 /ø |
150 V range | 22.2 | 37.0 | 22.2 /ø | |
Note: Constant power mode provides increased current at reduced voltage (See chart below) |
Model | Model | 10001 i/iX | 15001 i/iX | 15003 i/iX 3ø |
Steady State AC Current | 300 V range | 37.0 | 55.5 | 18.5 /ø |
150 V range | 74.0 | 111.0 | 37.0 /ø | |
Note: Constant power mode provides increased current at reduced voltage (See chart below) |
Model | Model | 3001 i/iX | 5001 i/iX | 9003 i/iX 3ø |
Peak Repetitive AC Current | High range | 96.0 | 96.0 | 96.0 /ø |
Low range | 110.0 | 110.0 | 110.0 /ø |
Model | Model | 10001 i/iX | 15001 i/iX | 15003 i/iX 3ø |
Peak Repetitive AC Current | High range | 192.0 | 288.0 | 96.0 /ø |
Low range | 220.0 | 330.0 | 110.0 /ø |
Programming Accuracy | Voltage (rms): ± 0.2 of range, 16 to 1000 Hz, Frequency: ± 0.01 % of programmed value, Current Limit: ± 0.5 % of programmed value, Phase: < 1.5° with balanced load at 50/60 Hz |
Programming Resolution | Voltage (rms): 100 mV, Frequency: 0.01 Hz from 16 - 81.91 Hz, 0.1 Hz from 82.0 - 819.1 Hz, 1 Hz from 820-1000 Hz, Current Limit: 0.1 A, Phase, 0.1° |
Output Relay | Push-button controlled or bus controlled output relay |
Output Impedance (iX Only) | Programmable Z on 3001iX, 5001iX, 9003iX and 15003iX (3ø mode only) for 50 Hz fundamental |
Resistive | Range: 17 - 1000 mOhm,resolution: 4 mOhm accuracy, 2 % FS |
Inductive | Range: 230 - 1000 μH, resolution: 4 μH, accuracy: 2 % FS |
Constant Power AC Mode - Available Max. AC Current |
V-F Rating Chart - 300 Volt Range |
Measurements - Standard (AC Measurements) | ||||
Parameter | Frequency | RMS Voltage | RMS Current | Peak Current |
Range | 16-500 Hz | 0-300 V | 0-40 A | 0-120 A |
Accuracy* (±) 0.01% + 0.01 Hz | < 100 Hz 100 - 500 Hz | 0.5 V + 0.02% 0.1 V + 0.02% | 0.5 A + 0.02% 0.1 A + 0.02% | 0.5 A + 0.02% 0.1 A + 0.02% |
Resolution* | 0.01 Hz | 10 mV | 1 mA | 1 mA |
Parameter | Crest Factor | Real Power | Apparent Pwr | Pwr Factor |
Range | 0.00-6.00 | 0-6 kW | 0-6 kVA | 0.00-1.00 |
Accuracy* (±) 0.01% + 0.01 Hz | 0.05 0.05 | 10 W + 0.1% 20 W + 0.1% | 10 VA + 0.1% 20 VA + 0.1% | 0.01 0.02 |
Resolution* | 0.01 | 1 W | 1 VA | 0.01 |
Parameter | DC Voltage | DC Current | Power |
Voltage Ranges | 0-300 V | 0-40 A | 0-6 kW |
Accuracy* (±) 0.01% + 0.01 Hz | 150 mV 150 mV | 70 mA 70 mA | 15 W 15 W |
Resolution* | 10 mV | 1 mA | 1 W |
* Measurement system bandwidth = DC to 48 kHz. Accuracy specifications are valid above 100 counts. Current and Power Accuracy specifications are times two for 10001i/iX /30003i/iX and times three for 15001i/iX and 9003i/iX and 15003i/iX with MODE-iX option when in single phase mode. For 10001i/iX, 15001i/iX and 30003i/ iX, resolution decreases by factor of 10, ranges for current and power increases by factor of three. PF accuracy applies for PF > 0.5 and VA > 50% of range. |
Measurements - Harmonics | ||||
Parameter | Frequency Fundamental Harmonics | Phase | Voltage | Current |
Range | 16.00-500.0 Hz / 32.00 Hz - 48.00 kHz | 0.0 - 360.0° | Fundamental Harmonics 2 - 50 | Fundamental Harmonics 2 - 50 |
Accuracy* (±) | 0.01% + 0.01 Hz | 2° typ. | 250 mV 0.1% + 250 mV+0.1% /1 kHz | 50 mA/0.1% + 50 mA +0.1% /1 kHz |
Resolution | 0.01 Hz | 0.5° | 10 mV / 10 mV | 10 mA / 10 mA |
* Accuracy specifications are valid above 100 counts. Accuracy specifications are times three for three phase mode. Harmonics frequency range in three phase mode is 32 Hz - 16 kHz. Resolution decreases by factor of 10 for 9003iX and 15003iX with Mode-iX option in 1 phase mode and for 10001iX, 15001iX and 30003i/iX. |
DC Mode Output | |
Power (Max at full scale of DC Voltage Range) | 3001i/iX: 2100 W, 5001i/iX: 3500 W, 9003i/iX: 2100 W/ø 3ø, 6300 W/ø 1ø, 10001i/iX: 7000 W, 15001i/iX: 10500 W, 15003i/iX: 3500 W/ø 3ø, 10500 W/ø 1ø |
Voltage Ranges | Range: Low: 200 Vdc, High: 400 Vdc |
Line Regulation | < 0.1% FS or 10% line change |
Output Noise | < 250 mV rms typ., < 500 mV rms max., (20 kHz to 1 MHz) |
Max DC Current (Maximum current at 65% of V Range) | ||||
Model | 3001 i/iX | 5001 i/iX | 9003 i/iX | 9003 i/iX 3ø |
400V range | 7.8 | 13 | 23.4 | 7.8 |
200V range | 15.6 | 26 | 46.8 | 15.6 |
Model | 10001 i/iX | 15001 i/iX | 15003 i/iX 3ø |
400V range | 26 | 39 | 13 |
200V range | 52 | 78 | 26 |
Current Limit | Programmable from 0 A to maximum current for selected range |
AC+DC Mode Output | |
Output Power (iX only) | Full AC Power if DC component is less than 20% of full scale voltage, Full DC power if DC component is above 20% |
Storage | |
Non Volatile Mem. storage | 16 instrument setups, 200 user defined waveforms |
Waveforms | |
Waveform Types | i Series II: Sine, iX Series II: Sine, Square, Clipped sine, User defined |
User defined waveform storage | Four groups of 50 user defined arbitrary waveforms of 1024 points for a total of 200 (One group can be active at a time) |
System Interface | |
Inputs | Remote shutdown, External Sync, Clock/Lock (option) |
Outputs | Function Strobe, Clock/Lock (option) |
Protection | |
Over Load | Constant Current or Constant Voltage mode |
Over Temperature | Automatic shutdown |
Remote Control | |
IEEE-488 Interface | IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax |
RS232C Interface | 9 pin D-shell connector, Handshake: CTS, RTS, Data bits: 7,8, Stop bits: 1, 2, Baud rate: 9600, 19200, 38400, 57600, 115200, IEEE-488.2 SCPI Syntax (Supplied with RS232C cable) |
DC Mode Output | |
Voltage | 3001 and 9003: 208-240 ± 10% Vac, (L-N, 1ø), All other models: Standard: 208-240 ± 10% Vac, (L-L, 3ø), Option -400: 400-480 ± 10% Vac, (L-L, 3ø) (Input range must be specified when ordering) |
Max DC Current (Maximum current at 65% of V Range) | |||
Model | 3001i/iX | 5001i/iX | 9003i/iX |
187-264V | 25 A | 23 A | 75 A |
360-528V | N/A | 12 A | N/A |
Model | 10001 i/iX | 15001 i/iX | 15003 i/iX 3ø |
187-264V | 46 A | 69 A | 69 A |
360-528V | 24 A | 36 A | 36 A |
Inrush Current per chassis | < 100 Apk for 100 μs at 208-240 V, < 50 Apk for 100 μs at 400-480 V |
Line Frequency | 50-60 Hz ± 10 % |
Efficiency | 75% typical |
Power Factor | 0.6 typical |
AC Service | |
Regulatory | IEC61010, EN50081-2, EN50082-2, CE EMC and Safety Mark requirements |
RFI Suppression | CISPR 11, Group1 , Class A |
Rear Panel Connectors | AC Input & Output terminal block with cover, IEEE-488 (GPIB) connector (rear panel), 9 pin D-Shell RS232C connector*, Remote voltage sense terminal block, System Interface Connector, *RS232 DB9 to DB9 cable supplied |
Physical Dimensions | |
Dimensions | Height: 7” (178 mm), Width: 19” (483 mm), Depth: 24” (610 mm) (depth includes rear panel connectors) |
Weight | per 5001i/iX Chassis: Net: 61 lbs / 28 Kg, Shipping: 115 lbs / 52 Kg |
Vibration and Shock | Designed to meet NSTA project 1A transportation levels |
Air Intake/Exhaust | Forced air cooling, side air intake, rear exhaust. |
Operating Humidity | 0 to 95 % RAH, non condensing. |
Temperature | Operating: 0 to 40° C, Storage: -20 to +85° C |
具有单电压范围的标准控制器版本 | ||||
型号 | 输出功率 AC | 相位输出 | 低 V AC | 电流范围 DC |
3001i/iX | 3 kVA | 1 | 22 | 15.6 |
5001i/iX | 5 kVA | 1 | 37 | 26 |
5001i/iX-400 | 5 kVA | 1 | 37 | 26 |
9003iX¹ | 9 kVA | 3 | 22 | 15.6 |
10001i/iX¹ | 10 kVA | 1 | 74 | 52 |
10001i/iX-400¹ | 10 kVA | 1 | 74 | 52 |
10002i/iX¹ | 10 kVA | 2 | 37 | 26 |
10002i/iX-400¹ | 10 kVA | 2 | 37 | 26 |
15001i/iX¹ | 15 kVA | 1 | 111 | 78 |
15001i/iX-400¹ | 15 kVA | 1 | 111 | 78 |
15003i/iX¹ | 15 kVA | 3 | 37 | 26 |
15003i/iX-400¹ | 15 kVA | 3 | 37 | 26 |
型号 | 每相高 V AC | 范围 DC | 输入电压² |
3001i/iX | 11 | 7.8 | 208-240V |
5001i/iX | 18.5 | 13 | 208-240V |
5001i/iX-400 | 18.5 | 13 | 400-480V |
9003iX¹ | 11 | 7.8 | 208-240V |
10001i/iX¹ | 37 | 26 | 208-240V |
10001i/iX-400¹ | 37 | 26 | 400-480V |
10002i/iX¹ | 18.5 | 13 | 208-240V |
10002i/iX-400¹ | 18.5 | 13 | 400-480V |
15001i/iX¹ | 55.5 | 39 | 208-240V |
15001i/iX-400¹ | 55.5 | 39 | 400-480V |
15003i/iX¹ | 18.5 | 13 | 208-240V |
15003i/iX-400¹ | 18.5 | 13 | 400-480V |
注 (1) 随系统接口电缆一起提供。主控单元中的控制器。 |
可选附件 | |
-400 | 400-480 伏线到线交流输入。 |
-411 | IEC61000-4-11 测试固件。另请参见 EOS1/3。 |
-413 | IEC61000-4-13 谐波和间谐波测试固件。 |
-EOS-1 | IEC61000-4-11 电子输出开关(1 相)包括 -411 选件。详情请参见 EOS 数据表。 |
-EOS-3 | IEC61000-4-11 电子输出开关(3 相)包括 -411 选件。详情请参见 EOS 数据表。 |
-LKM | 时钟/锁定主设备 |
-LKS | 时钟/锁定辅助设备 |
-LNS | 内部交流线路同步 |
-FC | 将输出频率控制更改为 ±0.25% |
-MODE-iX | 在 1 到 3 相输出模式之间切换,仅适用于 9003iX 或 15003i/iX。 |
OMNI-1-18i | 单相 3001i/iX 或 5001i/iX 的阻抗匹配网络,支持 IEC-1000-3-3 闪烁测试。 |
OMNI-3-18i | 三相 9003iX 或 15003i/iX 系统的阻抗匹配网络,支持 IEC-1000-3-3 闪烁测试。 |
OMNI-3-37i | 三相 30003i/iX 系统的阻抗匹配网络,支持 IEC-1000-3-3 闪烁测试。 |
-RMS | 机架式滑轨 |
-WHM | 瓦时测量选件 |
-XLS | 外部交流线路同步适配器。 (-LNS 和 XLS 互斥) |
机柜 | 多箱 iX 系列 II 系统可以在出厂前安装在 19 英寸机柜中并接好线。订购机柜配置时,请在型号前加上 C1-C4 前缀。有关价格和详细信息,请联系工厂。 |
航空电子设备测试常规选件 | |
-ABD | 空客指令 0100.1.8 测试 |
-AMD | 空客 AMD24 测试。 |
-A350 | 空客 A350 测试。 |
-AIRB | 空客测试包(A380、A350、AMD24) |
-B787 | 波音 787B3-0147 测试 |
-160 | RTCA/DO-160D 和 EUROCAE 测试固件。详情请参阅 -160 选件数据表。 |
*注意 有关性能功能的完整列表,请参阅航空电子设备测试用户手册 P/N 4994-971。 |
特点比较 | |||
控制器 | i | iX | |
交流模式 | x | x | |
直流模式 | x | x | |
交流 + 直流模式 | - | x | |
瞬态编程 | x | x | |
任意波形 | - | x | |
测量 | x | x | |
谐波测量 | - | x | |
波形采集 | - | x | |
程控阻抗 | - | x | |
IEEE / RS232 | x | x |