品牌
其他厂商性质
所在地
液体密度计是根据双U型管内充满不同介质时震荡频率不同的原理进行液体密度测量的。将待测液体泵入谐振筒传感器后,由单片机进行测量数据处理,快速直接,而且灵敏度高。它是由双音叉式密度传感器、振筒电路、测温电路、CPU、显示器、恒温槽、进液泵及控制面板组成。该液体密度计可广泛用于各种液体密度的测量,且配合不同的浓度转换软件,还能直接读出相应液体的浓度值,如酒精,通过单片机软件的处理,可直接读出体积浓度数据,测试更为方便。
产品型号和主要参数概况
货号 | ETT-005 | ETT-01 | ETT-02 | ETT-05 | ETT-08 | ETT-10 | |
主要技术参数 | 测量范围 | 0~1999.99kg/m3 | 0~1999.99kg/m3 | 0~1999.9kg/m3 | 0~1999.9kg/m3 | 0~1.9999g/cm3 | 0~1.999g/cm3 |
示值误差 | ±0.05kg/m3 | ±0.1kg/m3 | ±0.2kg/m3 | ±0.5kg/m3 | ±0.0008g/cm3 | ±0.001g/cm3 | |
恒温控制 | 20℃±0.05℃ | 20℃±0.05℃ | 20℃±0.05℃ | 20℃±0.1℃ | 20℃±0.1℃ | 20℃±0.1℃ | |
采样量 | 2ml/次 | 2ml/次 | 2ml/次 | 2ml/次 | 2ml/次 | 2ml/次 | |
数据存贮 | 80组 | 80组 | 80组 | 80组 | 80组 | 80组 | |
环境要求 | 5℃~35℃ | 5℃~35℃ | 5℃~35℃ | 5℃~35℃ | 5℃~35℃ | 5℃~35℃ | |
供电电源 | 220V±22V,50Hz±1Hz,50VA | 220V±22V,50Hz±1Hz,50VA | 220V±22V,50Hz±1Hz,50VA | 220V±22V,50Hz±1Hz,50VA | 220V±22V,50Hz±1Hz,50VA | 220V±22V,50Hz±1Hz,50VA | |
功 能 特 点 | 1.六位数码密度值显示。 | 1.六位数码密度值显示。 | 1.六位数码密度值显示。 | 1.五位数码密度值显示。 | 1.五位数码密度值显示。 | 1.四位数码密度值显示。 | |
2.恒温控制20℃±0.1℃(恒温值可根据用户要求定做)。 3.键控操作,自动采样。 4.内壁免挂壁处理。 5.数据可回调删除(可定做数据传输和数据打印功能)。 6.用20℃纯水校准。 |
外型尺寸:206cm×205cm×200cm
仪器重量:3.2Kg
ETT series electronic liquid densitometer
1. General :
ETT series electronic densitometer works on basis of the principle of vibration frequency variation in different media what filled fully in U shape pipe for measuring the media density. the micro processor shall process the measured data from the sensor mounted in the resonator with quick, direct and high precision features. The unit consists of double tuning fork sensor, circuit of vibration cylinder, temperature measurement circuit, CPU, display screen, constant temperature chute, filling pump and control panel. Combined with various density converting software the direct reading of concentration of various liquid is available. Such as alcohol, may be processed by single-chip processor software to read out directly the data of volume concentration, making the test more convenient.
2. Functions :
1.Constant temperature control :for the reason of the impacts of temperature to the density of liquid therefore the measured density shall be converted into the density at 20℃. but in herein device the temperature of the constant temperature chute shall be controlled within the range of 20℃±0.1℃ and the sensor as well as the sample liquid enclosed in the chute , the single-chip processor and the sensor for resonator shall be engaged for the temperature control. so that the error and the complication of the conversion can be avoided and the precision, stability and repeat can be guaranteed(the constant temperature chute can be custom-built.)。Double bladders are arranged for constant temperature control with better seal and stability.
2.Direct reading of density for 20℃ of liquid and indication of temperature:The single -chip processor work out the density of liquid on basis of the mathematic model of frequency to liquid density of sensor and the measured frequency of vibration, then carry out the floating-point mathematics for avoiding the extra error caused by the insufficient precision. The digital reading of density calculated by the processor is displayed and the temperature display also available.
3.Automatic sampling:Creep pump controlled by the single-chip processor and driven by stepping motor make the system running at high level of automation.
4.Free remainder treatment arrangement:The remainder of liquid on the inner wall of the resonator tube after liquid flow may impact the precision of measurement therefore the free remainder treatment to the inner wall of the resonating tube can guarantee the precision of the device.
5.Acid and alkali resistant pipe:The entire pipe contacting the liquid shall be acid and alkali resistant pipe for application of acid or alkali liquid.
6. Data storing :In-built memory chip for storing 80 groups of measured data, the recall and delete function are available.
7.Subsidiary function :Special software is available for reading of liquid concentration at various temperatures as per client's application.
8.Clalibration :the device can be calibrated with pure water at 20℃ for correct its shifting caused of long time off -position which is not available in normal glass densitometer.
3. The new advantages:
1. Double U-shape resonating sensor adopted for the liquid density measurement that making measurement quick and with higher precision comparing with the conventional method of mass to volume ratio.
2.In addition to the advantage of constant temperature feature at 20℃ the double bladder constant temperature arrangement can keep the higher stability and resistant to circumstance.
Types and specifications
type No. | ETT-005 | ETT-01 | ETT-02 | ETT-05 | ETT-08 | ETT-10 | |
specification | range | 0~1999.99kg/m3 | 0~1999.99kg/m3 | 0~1999.9kg/m3 | 0~1999.9kg/m3 | 0~1.999g/cm3 | 0~1.999g/cm3 |
indication error | ±0.05kg/m3 | ±0.1kg/m3 | ±0.2kg/m3 | ±0.5kg/m3 | ±0.0008g/cm3 | ±0.001g/cm3 | |
constant temperature control | 20℃±0.05℃ | 20℃±0.05℃ | 20℃±0.05℃ | 20℃±0.1℃ | 20℃±0.1℃ | 20℃±0.1℃ | |
sampling | 2ml/one time | 2ml/one time | 2ml/one time | 2ml/one time | 2ml/one time | 2ml/one time | |
data storing | 80 groups | 80 groups | 80 groups | 80 groups | 80 groups | 80 groups | |
ambient condition | 5℃~35℃ | 5℃~35℃ | 5℃~35℃ | 5℃~35℃ | 5℃~35℃ | 5℃~35℃ | |
power | 220V±22V,50Hz±1Hz,50VA | 220V±22V,50Hz±1Hz,50VA | 220V±22V,50Hz±1Hz,50VA | 220V±22V,50Hz±1Hz,50VA | 220V±22V,50Hz±1Hz,50VA | 220V±22V,50Hz±1Hz,50VA | |
indication | one 6 digitals indication of density | one 6 digitals indication of density | one 6 digitals indication of density。 | one 5 digitals indication of density。 | one 5 digitals indication of density | one 4 digitals indication of density |
Dimension :206mm×205mm×200mm
Weight:3.2Kg